Hantek 1008c Automotive Oscilloscope/DAQ/Programmable Generator + Auto Ignition Probe สโคปเช็คอาการของเพลารถ,จุดระเบิดของรถยนต์
- Cost-effective Hantek PC USB 8CH Automotive Diagnostic Oscilloscope/DAQ/Programmable Generator: Highly efficient and cost -effective;
- 8 channels oscilloscope for vehicle testing;
- Auto Ignition Probe;
- 2.4MSa/s real time sampling rate, 12bit vertical resolution;
- spectrum analysis function;
- 10mV/div to 5V/div input sensitivity;
- DAQ card function;
- 8 channels programmable generator which can analog signals of crankshaft, camshaft, etc.
Specification
(1) Vehicle Testing
- First Diagnosis: Intake manifold vacuum & ignition, Petrol fumes adjusting valve vacuum & ignition, Idle exhaust ignition, Starting exhaust ignition
- Ignition: primary and secondary
- Sensor: Air Flow Meter, Camshaft, Crankshaft, Distributor, Lambda sensor, Throttle position
- Bus Diagnosis: CAN bus data examine, CAN bus signal integrity, CAN bus LH long time acquisition, LIN bus
- Performer: Petrol/Diesel
- Starter and charging circuits
(2) Oscilloscope
- 8 channels oscilloscope, 2.4MSa/s real time sampling rate
- 12 bits vertical resolution, spectrum analysis function
(3) Programmable Generator
- 8 channels programmable generator
- Can analog signals of crankshaft, camshaft etc.
(4) Others
- USB 2.0 interface plug and play, and no need extra power supply;
- More than 20 types of automatic testing function, a similar interface with benchtop oscilloscope, easy to use;
NOTE: Software support: Windows NT, Window 2000, Windows XP, VISTA, Windows 7,Window 8,Window 10
Model |
Hantek1008C |
|
Oscilloscope Mode |
||
Vertical |
Analog Channel |
8 |
Input Impedance |
Resistance: 1MΩ |
|
Input Sensitivity |
10mV/div to 5V/div |
|
|
Input Coupling |
DC |
Resolution |
12 bits |
|
Horizontal |
Memory Depth |
4K |
Max. Input |
400V (DC+AC Peak) |
|
Real-Time Sampling Rate |
2.4MSa/s |
|
Time Base Range |
1ns/div to 20000s/div(1-2-5 sequences) |
|
Time Base Precision |
±50ppm |
|
Trigger |
Source |
CH1, CH2,CH3,CH4, CH5, CH6,CH7,CH8 |
Mode |
Edge |
|
X-Y Mode |
X-Axis Input |
CH1 |
Y-Axis Input |
CH2 |
|
Cursors and Measurement |
Voltage Measurement |
Vpp, Vamp, Vmax, Vmin, Vtop, Vmid, Vbase,Vavg, Vrms, Vcrms, Preshoot, Overshoot |
Time Measurement |
Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width, Duty Cycle |
|
Cursors Measurement |
Horizontal ,Vertical, Track, Auto Measure Modes |
|
Waveform Signal Process |
|
+,- , x,÷, FFT, Invert |
Voltage Range |
|
10mV to 5V/div @ x 1 probe |
100mV to 50V/div @ x 10 probe |
||
10V to 5000V/div @ x 1000 probe |
||
100V to 50000V/div @ x 10000 probe |
||
200mV to 100V/div @ 20:1 |
||
Current Range |
|
100mA to 50.0A/div @ CC65(20A) |
1000mA to 500.0A/div @ CC65(65A) |
||
1A to 100.0A/div @ CC650(60A) |
||
10A to 1000.0A/div @ CC650(650A) |
||
1A to 200.0A/div @CC1100(100A) |
||
10A to 2000.0A/div @CC1100(1100A) |
||
Cursor |
|
Time/frequency difference, voltage difference |
FFT |
|
Rectangular, Hanning, Hamming, Blackman Window |
Math |
|
Addition, subtraction, multiplication, division |
Programmable Generator |
||
Channel |
|
8 |
Output Level |
|
LVTTL |
Frequency Range |
|
0-250kHz |
Interface |
|
USB 2.0 |
Power |
|
No need extra power supply |
Measurement |
Size |
185 x 150 x 27 (mm) |
Weight |
0.35KG |
- 1 Pcs x 1008C DAQ oscilloscope
- 8 Pcs x Crocodile probes/cabl
- 1 Pcs x USB Cable
- 1 Pcs x CD (driver etc.)
- 1 Pcs x Bag
- 1 Pcs x HT25 Probe