ตะกร้า

Hantek MSO5102D 2 in 1 Digital Oscilloscope 100MHz 2CH 1GSa/s 16CH Logic Analyzer สโคป + ฟังก์ชั่นวิเคราะห์สัญญาณลอจิก

สั่งผ่านไลน์ได้เลยรบกวน @thaihotairtool (มี@นะครับ)
รหัสสินค้า
HT-MSO5102D
ราคาพิเศษ ฿15,350.00 ราคาปรกติ ฿18,420.00

Features:

  • 100MHz bandwidth.
  • 1GSa/s Real Time sample rate.
  • Large (7.0-inch) color display, WVGA(800x480).
  • Record length up to 1M.
  • Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
  • USB host and device connectivity, standard.
  • Multiple automatic measurements.
  • Four math functions, including FFTs standard.
  • VGA Optional.

 

 

Model MSO5102D
Acquisition
Sample Rate

Real-Time Sample: 1GS/s

Equivalent Sample: 50GS/S

Acquisition Modes
Normal Normal data only
Peak Detect High-frequency and random glith capture
Average Waveform Average, selectable 4.8.16,32.64.128
Inputs
Inputs Coupling AC, DC. GND
Inputs Impedance Sample Rate 1MΩ±2%ll20pF±3pF
Probe Attenuation 1X,10X
Supported Probe Attenuation Factor 1X,10X,100X,1000X
Maximum Input Voltage CAT I and CAT II: 300VRMS (10x), Installation Category;
CAT III: 150VRMS(1x);
Installation Category II: derate at20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur
Horizontal
Sample Rate Range 500MS/S - 1GS/S
Waveform Interpolation (sin x)/x
Record Length 1M
SEC/DIV Range 4ns/div to 40s/div
Sample Rate and Delay Time Accuracy ±50ppm (at over any≥ 1ms time interval)
Position Range

20ns/div to 80us/div; (-8divx s/div) to 40ms;

200us/div to 40s/div; (-8divx s/div) to 400s;

Delta Time Measurement
Accuracy
(Full Bandwidth)
Single-shot. Normal mode:± (1 sample interval +100ppm x reading + 0.6ns); >16 averages:! (1 sample interval + 100ppm x reading + 0.4ns);
Sample interval = s/div + 200
Vertical System
Vertical Resolution 8-bit resolution, all channel sampled simultaneously
Position Range 2mV/divto 10V/div
Bandwidth 100MHz
Rise Time at BNC( typical) 3.5ns

 

Position Range 2mV/div to 20mV/div, ±400mV
50mV/div to 200mV/div, ±2V
500mV/div to 2V/div, ±40V
5V/div to 10V/div, ±50V
Math +, -,x, /, FFT
FFT

Windows: Hanning% Flatop% Rectamgulars Bartletts

Blackman: 1024 sample point

Bandwidth Limit 20MHz
Low Frequency Response (-3db) ≤ 10HZ at BNC
DC Gain Accuracy

±3% for Normal or Average acquisition mode. 10V/div to 10mV/div;

±4% for Normal or Average acquisition mode. 5mV/div to 2mV/div

DC Measurement Accuracy, Average Acquisition Mode When vertical displacement is zero, and N s16:± (3% x reading + 0.1div + 1mV) only 10mV/div or greater is selected;
When vertical displacement is not zero, and Ns16: ± (3% x reading + vertical position) +1% of vertical position + 0.2div); Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div
Volts Measurement Repeatability,
Average Acquisition Mode
Delta volts between any two averages of si 6 waveforms acquired under same setup and ambient conditions
Trigger System
Trigger Types Edge, Video, Pulse, Slope, Overtime, Alternative
Trigger Source CH1, CH2, EXT, EXT/5, AC Line
Trigger Modes Auto, Normal, Single
Coupling Type DC, AC, Noise Reject, HF Reject, LF Reject
Trigger Sensitivity (Edge Trigger Type) DC(CH1,CH2):
1div from DC to 10MHz;l5divfrom 10MHzto 100MHz; 2divfrom 100MHzto Full; DC(EXT): 200mVfrom DC to 100MHz; 350mVfrom 100MHz to 200MHz;
DC(EXT/5): 1V from DC to 100MHz; 1.75Vfrom 100MHzto 200MHz;
AC: Attenuates signals below 10Hz HF Reject: Attenuates signals above 80KHz;
LF Reject: Same as the DC-coupled limits for frequencies ab
Trigger Level Range CH1/CH2: ±8 divisions from center of screen; EXT:±1.2V;
EXT/5:±6V
Trigger Level Accuracy(typical)Accuracy is for signals having rise and fall times≥20ns

CH1/CH2:0.2div x volts/div within ±4 divisions from center of screen; EXT: ± (6% of setting + 40mV);
EXT/5: ± (6% of setting + 200mV);
Set Level to 50%(typical) Operates with input signals ≥50Hz

 

Video Trigger  
Video Trigger Type

CH1, CH2: Peak-to-peak amplitude of 2 divisions;

EXT: 400mV;

EXT/5:2V
Signal Formats and Field Rates. Video Trigger Type Supports NTSC, PAL and SECAM broadcast systems for any field or any line
Holdoff Range 100ns ~10s
Pulse Width Trigger  
Pulse Width Trigger Mode Trigger when (<,>, = ); Positive pulse or Negative pulse
Pulse Width Trigger Point Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
Less than: The trigger point is the trailing edge.
Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width
Pulse Width Range 20ns ~10s
Slope Trigger  
Slope Trigger Mode Trigger when (<,>, = ); Positive slope or Negative slope
Slope Trigger Point Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.
Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
Less than: The oscilloscope triggers when the waveform slope is less than the set slope. Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Time Range 20ns ~10s
Overtime Trigger  
Over Time Mode Rising edge or Falling edge
Time Range 20ns ~10s
Alternative Trigger  
Trigger on CH1 Internal Trigger: Edge. Pulse Width, Video, Slope
Trigger on CH2 Trigger on CH2 Internal Trigger: Edge. Pulse Width, Video, Slope
Trigger Frequency Counter  
Readout Resolution 6 digits
Accuracy (typical) ±30ppm (including all frequency reference errors and ±1 count errors)
Frequency Range AC coupled, from 4Hz minimum to rated bandwidth

 

Signal Source Pulse Width or Edge Trigger modes: all available trigger sources The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.
Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as trigger able events, such as narrow pulses in a narrow pulse train if set to < mode and the width is set to a relatively small time.
Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
Video Trigger mode: The Frequency Counter does not work.
Measurement
Cursor Measurement

Voltage difference between cursors: V

Time difference between cursors:T

Reciprocal of T in Hertz (1/T)

Auto Measurement Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width. -Pulse Width. Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean. Preiod RMS, FOVShoot, RPREShoot,BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF
Logic Analyzer Specifications
Channels 16 Channels
Max.Impedance Input 200K(C=10p)
Input Voltage Range -60V~60V
Logic Threshold Range -8V-8V
Max. Sample Rate 500MHz
Compatible Input TTL, CMOS, ECL
Sample Depth 512K
Trigger
Edge Trigger D0-D15 select slope (rising or falling edge)
Pulse Width D0-D15 select pulse polarity (positive or negative pulse), trigger when (=, >, <), trigger pulse width
Code-type D0-D15 select code-type (H, L, X)
Duration D0-D15 select persist time and trigger when (data terminate, data start, and data delay)
Queue D0-D15 select specific data index (0-3) and code-type (H, L, X)
Repeat D0-D15 select code-type (H, L, X) and repeat times
General Features  
Display  
Display Type 7 inch 64K color TFT (diagonal liquid crystal)
Display Resolution 800 horizontal by 480 vertical pixels
Display Contrast Adjustable (16 gears) with the progress bar
Probe Compensator Output  
Output Voltage( typical) About 5Vpp into slMQ load
Frequency(typical) 1kHz
Power Supply  
Supply Voltage

100-120VACRMS(±10%).45Hz to 440Hz, CATII

120-240VACRMS(±10%).45Hz to 66Hz, CATII

Power Consumption <30W
Fuse 2A, T rating, 250V
Environmental  
Temperature Operating: 32℉ to 122℉(0℃ to 50℃); Non operating: -40℉to 159.85℉(-40℃to +71℃)
Cooling Method Convection
Humidity ≤+104℉(≤+40℃): ≤90% relative humidity
106℉~122°F (+41℃ ~50℃): ≤60% relative humidity
Altitude Operating: Below 3,000m (10,000 feet); Non operaring: Below 15,000m(50,000 feet)

 

Package Included:

1 x Oscilloscope
2 x probe
1 x power cable
1 x USB cable
18 x logic accessories
1 x logic wire
6 x color circle
1 x probe cap
1 x CD

 

เขียนรีวิวสินค้าของคุณเอง
คุณกำลังรีวิว:Hantek MSO5102D 2 in 1 Digital Oscilloscope 100MHz 2CH 1GSa/s 16CH Logic Analyzer สโคป + ฟังก์ชั่นวิเคราะห์สัญญาณลอจิก