Features:
- 100MHz bandwidth.
- 1GSa/s Real Time sample rate.
- Large (7.0-inch) color display, WVGA(800x480).
- Record length up to 1M.
- Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
- USB host and device connectivity, standard.
- Multiple automatic measurements.
- Four math functions, including FFTs standard.
- VGA Optional.
Model |
MSO5102D |
Acquisition |
Sample Rate |
Real-Time Sample: 1GS/s
Equivalent Sample: 50GS/S
|
Acquisition Modes |
Normal |
Normal data only |
Peak Detect |
High-frequency and random glith capture |
Average |
Waveform Average, selectable 4.8.16,32.64.128 |
Inputs |
Inputs Coupling |
AC, DC. GND |
Inputs Impedance Sample Rate |
1MΩ±2%ll20pF±3pF |
Probe Attenuation |
1X,10X |
Supported Probe Attenuation Factor |
1X,10X,100X,1000X |
Maximum Input Voltage |
CAT I and CAT II: 300VRMS (10x), Installation Category; CAT III: 150VRMS(1x); Installation Category II: derate at20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur |
Horizontal |
Sample Rate Range |
500MS/S - 1GS/S |
Waveform Interpolation |
(sin x)/x |
Record Length |
1M |
SEC/DIV Range |
4ns/div to 40s/div |
Sample Rate and Delay Time Accuracy |
±50ppm (at over any≥ 1ms time interval) |
Position Range |
20ns/div to 80us/div; (-8divx s/div) to 40ms;
200us/div to 40s/div; (-8divx s/div) to 400s;
|
Delta Time Measurement Accuracy (Full Bandwidth) |
Single-shot. Normal mode:± (1 sample interval +100ppm x reading + 0.6ns); >16 averages:! (1 sample interval + 100ppm x reading + 0.4ns); Sample interval = s/div + 200 |
Vertical System |
Vertical Resolution |
8-bit resolution, all channel sampled simultaneously |
Position Range |
2mV/divto 10V/div |
Bandwidth |
100MHz |
Rise Time at BNC( typical) |
3.5ns |
Position Range |
2mV/div to 20mV/div, ±400mV |
50mV/div to 200mV/div, ±2V |
500mV/div to 2V/div, ±40V |
5V/div to 10V/div, ±50V |
Math |
+, -,x, /, FFT |
FFT |
Windows: Hanning% Flatop% Rectamgulars Bartletts
Blackman: 1024 sample point
|
Bandwidth Limit |
20MHz |
Low Frequency Response (-3db) |
≤ 10HZ at BNC |
DC Gain Accuracy |
±3% for Normal or Average acquisition mode. 10V/div to 10mV/div;
±4% for Normal or Average acquisition mode. 5mV/div to 2mV/div
|
DC Measurement Accuracy, Average Acquisition Mode |
When vertical displacement is zero, and N s16:± (3% x reading + 0.1div + 1mV) only 10mV/div or greater is selected; When vertical displacement is not zero, and Ns16: ± (3% x reading + vertical position) +1% of vertical position + 0.2div); Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div |
Volts Measurement Repeatability, Average Acquisition Mode |
Delta volts between any two averages of si 6 waveforms acquired under same setup and ambient conditions |
Trigger System |
Trigger Types |
Edge, Video, Pulse, Slope, Overtime, Alternative |
Trigger Source |
CH1, CH2, EXT, EXT/5, AC Line |
Trigger Modes |
Auto, Normal, Single |
Coupling Type |
DC, AC, Noise Reject, HF Reject, LF Reject |
Trigger Sensitivity (Edge Trigger Type) |
DC(CH1,CH2): 1div from DC to 10MHz;l5divfrom 10MHzto 100MHz; 2divfrom 100MHzto Full; DC(EXT): 200mVfrom DC to 100MHz; 350mVfrom 100MHz to 200MHz; DC(EXT/5): 1V from DC to 100MHz; 1.75Vfrom 100MHzto 200MHz; AC: Attenuates signals below 10Hz HF Reject: Attenuates signals above 80KHz; LF Reject: Same as the DC-coupled limits for frequencies ab |
Trigger Level Range |
CH1/CH2: ±8 divisions from center of screen; EXT:±1.2V; EXT/5:±6V |
Trigger Level Accuracy(typical)Accuracy is for signals having rise and fall times≥20ns
|
CH1/CH2:0.2div x volts/div within ±4 divisions from center of screen; EXT: ± (6% of setting + 40mV); EXT/5: ± (6% of setting + 200mV); |
Set Level to 50%(typical) |
Operates with input signals ≥50Hz |
Video Trigger |
|
Video Trigger Type |
CH1, CH2: Peak-to-peak amplitude of 2 divisions;
EXT: 400mV;
EXT/5:2V |
Signal Formats and Field Rates. Video Trigger Type |
Supports NTSC, PAL and SECAM broadcast systems for any field or any line |
Holdoff Range |
100ns ~10s |
Pulse Width Trigger |
|
Pulse Width Trigger Mode |
Trigger when (<,>, = ); Positive pulse or Negative pulse |
Pulse Width Trigger Point |
Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level. Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width. Less than: The trigger point is the trailing edge. Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width |
Pulse Width Range |
20ns ~10s |
Slope Trigger |
|
Slope Trigger Mode |
Trigger when (<,>, = ); Positive slope or Negative slope |
Slope Trigger Point |
Equal: The oscilloscope triggers when the waveform slope is equal to the set slope. Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope. Less than: The oscilloscope triggers when the waveform slope is less than the set slope. Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope. |
Time Range |
20ns ~10s |
Overtime Trigger |
|
Over Time Mode |
Rising edge or Falling edge |
Time Range |
20ns ~10s |
Alternative Trigger |
|
Trigger on CH1 |
Internal Trigger: Edge. Pulse Width, Video, Slope |
Trigger on CH2 |
Trigger on CH2 Internal Trigger: Edge. Pulse Width, Video, Slope |
Trigger Frequency Counter |
|
Readout Resolution |
6 digits |
Accuracy (typical) |
±30ppm (including all frequency reference errors and ±1 count errors) |
Frequency Range |
AC coupled, from 4Hz minimum to rated bandwidth |
Signal Source |
Pulse Width or Edge Trigger modes: all available trigger sources The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed. Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as trigger able events, such as narrow pulses in a narrow pulse train if set to < mode and the width is set to a relatively small time. Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity. Video Trigger mode: The Frequency Counter does not work. |
Measurement |
Cursor Measurement |
Voltage difference between cursors: V
Time difference between cursors:T
Reciprocal of T in Hertz (1/T)
|
Auto Measurement |
Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width. -Pulse Width. Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean. Preiod RMS, FOVShoot, RPREShoot,BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF |
Logic Analyzer Specifications |
Channels |
16 Channels |
Max.Impedance Input |
200K(C=10p) |
Input Voltage Range |
-60V~60V |
Logic Threshold Range |
-8V-8V |
Max. Sample Rate |
500MHz |
Compatible Input |
TTL, CMOS, ECL |
Sample Depth |
512K |
Trigger |
Edge Trigger |
D0-D15 select slope (rising or falling edge) |
Pulse Width |
D0-D15 select pulse polarity (positive or negative pulse), trigger when (=, >, <), trigger pulse width |
Code-type |
D0-D15 select code-type (H, L, X) |
Duration |
D0-D15 select persist time and trigger when (data terminate, data start, and data delay) |
Queue |
D0-D15 select specific data index (0-3) and code-type (H, L, X) |
Repeat |
D0-D15 select code-type (H, L, X) and repeat times |
General Features |
|
Display |
|
Display Type |
7 inch 64K color TFT (diagonal liquid crystal) |
Display Resolution |
800 horizontal by 480 vertical pixels |
Display Contrast |
Adjustable (16 gears) with the progress bar |
Probe Compensator Output |
|
Output Voltage( typical) |
About 5Vpp into slMQ load |
Frequency(typical) |
1kHz |
Power Supply |
|
Supply Voltage |
100-120VACRMS(±10%).45Hz to 440Hz, CATII
120-240VACRMS(±10%).45Hz to 66Hz, CATII
|
Power Consumption |
<30W |
Fuse |
2A, T rating, 250V |
Environmental |
|
Temperature |
Operating: 32℉ to 122℉(0℃ to 50℃); Non operating: -40℉to 159.85℉(-40℃to +71℃) |
Cooling Method |
Convection |
Humidity |
≤+104℉(≤+40℃): ≤90% relative humidity 106℉~122°F (+41℃ ~50℃): ≤60% relative humidity |
Altitude |
Operating: Below 3,000m (10,000 feet); Non operaring: Below 15,000m(50,000 feet) |
Package Included:
1 x Oscilloscope 2 x probe 1 x power cable 1 x USB cable 18 x logic accessories 1 x logic wire 6 x color circle 1 x probe cap 1 x CD
|